search

menu

  • Research Research
    • Where science meets inspired minds

    • Back
    • Research
    • Our Science
    • Research Groups
    • Facilities & Platforms
    • Clinical research
    • Find a researcher
    • Publications
    • Knowledge Transfer
  • Careers & study Careers & study
    • Become a leader in cancer research

    • Back
    • Careers & study
    • Vacancies
    • Faculty
    • Scientific staff
    • Scientific support staff
    • Postdoctoral fellows
    • PhD Students
    • Operational staff
    • Clinical fellows
    • Life in Amsterdam
    • Student internships
  • News & Events News & Events
    • Check out our stories and events

    • Back
    • News & Events
    • News
    • Media & Press
    • Calendar
  • About us About us
    • Maximum impact for cancer patients

    • Back
    • About us
    • Our vision
    • Organization
    • Collaborations
    • Responsible Research
    • Support us
    • Visit us
    • Contact us
  • Support us
Support us
  • Home
  • Publications
  • Research
  • Publications
  • Article

Target delineation variability and corresponding margins of peripheral early stage NSCLC treated with stereotactic body radiotherapy.

Heike Peulen ,
José Belderbos ,
Matthias Guckenberger ,
Andrew Hope ,
Inga Grills ,
Marcel van Herk ,
Jan-Jakob Sonke

Abstract

METHODS AND MATERIALS

Sixteen early stage NSCLC GTV's were delineated by 11 radiation oncologists from 4 institutes. A median surface was computed and the delineation variation perpendicular to this surface was measured (local standard deviation=SD). The overall target delineation variability was quantified by the root-mean-square (rms) of the local SD. The required margin was determined by expanding all delineations to encompass the median surface, where after the underlying probability distribution was modeled by a number of uncorrelated 'pimples-and-dimples'.

CONCLUSION

A relatively small target delineation uncertainty of 1.2mm-1.8mm (1SD) was observed for early stage NSCLC. A 3.4-5.9mm GTV-to-PTV margin was required to account for this uncertainty alone, ignoring other sources of geometric uncertainties.

RESULTS

The overall target delineation variability was 2.1mm (rms). Institute I-III delineated significantly smaller volumes than institute IV, yielding target delineation variabilities of 1.2mm and 1.8mm respectively. The margin required to obtain 90% coverage of the delineated contours was 3.4mm and 5.9mm respectively. The factor α in M=αΣ required to calculate adequate margins was 2.8-3.2, which is larger than the 2.5 found for 3D rigid target displacement.

PURPOSE

To quantify the target delineation variability in peripheral early stage lung cancer treated with SBRT and derive corresponding margins.

More about this publication

Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology

Volume 114
Issue nr. 3
Pages 361-6
Publication date 01-03-2015

Full text links

Publisher website (DOI) 10.1016/j.radonc.2015.02.011
Europe PubMed Central 25770872
Pubmed 25770872

Where science meets inspired minds

Contact

Plesmanlaan 121
1066CX Amsterdam

020 512 9111 communicatie@nki.nl

Quick links

  • Vacancies
  • News
  • Contact us
  • Media & Press

Follow us on

Disclaimer
Privacy statement
Cookies
Change cookie settings

This site uses cookies

This website uses cookies to ensure you get the best experience on our website.