search

menu

  • Research Research
    • Where science meets inspired minds

    • Back
    • Research
    • Our Science
    • Research Groups
    • Facilities & Platforms
    • Clinical research
    • Find a researcher
    • Publications
    • Knowledge Transfer
  • Careers & study Careers & study
    • Become a leader in cancer research

    • Back
    • Careers & study
    • Vacancies
    • Faculty
    • Scientific staff
    • Scientific support staff
    • Postdoctoral fellows
    • PhD Students
    • Operational staff
    • Clinical fellows
    • Life in Amsterdam
    • Student internships
  • News & Events News & Events
    • Check out our stories and events

    • Back
    • News & Events
    • News
    • Media & Press
    • Calendar
  • About us About us
    • Maximum impact for cancer patients

    • Back
    • About us
    • Our vision
    • Organization
    • Collaborations
    • Responsible Research
    • Support us
    • Visit us
    • Contact us
  • Support us
Support us
  • Home
  • Publications
  • Research
  • Publications
  • Article

Determination of ifosfamide, 2- and 3-dechloroethyifosfamide using gas chromatography with nitrogen-phosphorus or mass spectrometry detection.

T Kerbusch ,
M J Jeuken ,
J Derraz ,
J W van Putten ,
A D Huitema ,
J H Beijnen

Abstract

A comparison was made between methods for determining ifosfamide (IF), 2- (2DCE) and 3-dechloroethylifosfamide (3DCE) using gas chromatography with nitrogen-phosphorus detection (GC-NPD) versus positive ion electron-impact ion-trap mass spectrometry (GC-MS2). Sample pretreatment involved liquid-liquid extraction with ethyl acetate after adding trofosfamide as internal standard and alkalinization. The GC-NPD was linear, specific, and sensitive for all analytes in the range of 0.0500-100 microg/mL with lower limits of quantification (LLQ) of 0.0500 microg/mL using a 50-microgL plasma sample. The GC-MS2 was linear, specific, and sensitive for IF, 2DCE, and 3DCE in the ranges of 0.250-100, 0.500-25.0, and 0.500-25.0 microg/mL, respectively, with LLQs of 0.250, 0.500, and 0.500 microg/mL. The ranges of accuracy, within-day precision, and between-day precision for analysis of all compounds with GC-NPD did not exceed 93.3% to 105.4%, 8.0% and 9.8%, respectively. The ranges of accuracy, within-day precision, and between-day precision for analysis of all compounds with GC-MS2 did not exceed 86.5% to 99.0%, 9.0% and 12.7%, respectively. In conclusion, GC-NPD proved to be superior to GC-MS2 in sensitivity, detection range, accuracy, and precisions. Therefore GC-NPD is the method of choice for fast un-derivatized determination of IF, 2DCE, and 3DCE in human plasma, and it can readily be used for clinical pharmacokinetic studies and routine monitoring of IF-treated patients in a hospital setting.

More about this publication

Therapeutic drug monitoring

Volume 22
Issue nr. 5
Pages 613-20
Publication date 01-10-2000

Full text links

Publisher website (DOI) 10.1097/00007691-200010000-00018
Europe PubMed Central 11034269
Pubmed 11034269

Where science meets inspired minds

Contact

Plesmanlaan 121
1066CX Amsterdam

020 512 9111 communicatie@nki.nl

Quick links

  • Vacancies
  • News
  • Contact us
  • Media & Press

Follow us on

Disclaimer
Privacy statement
Cookies
Change cookie settings

This site uses cookies

This website uses cookies to ensure you get the best experience on our website.