search

menu

  • Research Research
    • Where science meets inspired minds

    • Back
    • Research
    • Our Science
    • Research Groups
    • Facilities & Platforms
    • Clinical research
    • Find a researcher
    • Publications
    • Knowledge Transfer
  • Careers & study Careers & study
    • Become a leader in cancer research

    • Back
    • Careers & study
    • Vacancies
    • Faculty
    • Scientific staff
    • Scientific support staff
    • Postdoctoral fellows
    • PhD Students
    • Operational staff
    • Clinical fellows
    • Life in Amsterdam
    • Student internships
  • News & Events News & Events
    • Check out our stories and events

    • Back
    • News & Events
    • News
    • Media & Press
    • Calendar
  • About us About us
    • Maximum impact for cancer patients

    • Back
    • About us
    • Our vision
    • Organization
    • Collaborations
    • Responsible Research
    • Support us
    • Visit us
    • Contact us
  • Support us
Support us
  • Home
  • Publications
  • Research
  • Publications
  • Article

Sensitive method for plasma and tumor Ko143 quantification using reversed-phase high-performance liquid chromatography and fluorescence detection.

Serge A L Zander ,
Jos H Beijnen ,
Olaf van Tellingen

Abstract

The fumitremorgin C analogue Ko143 is a potent and selective inhibitor of the ATP-binding cassette transporter ABCG2. To support in vivo ABCG2 resistance studies, we developed a sensitive and selective method for Ko143 quantification in plasma and tumor samples, using the parent compound fumitremorgin C as internal standard. Sample pretreatment by liquid-liquid extraction in diethyl ether yielded a recovery of 50% from human and mouse plasma. Pretreated samples were separated by reversed-phase high-performance liquid chromatography with fluorescence detection at 295nm excitation and 350nm emission wavelengths. Sharp chromatographic peaks were obtained with a 5μm GraceSmart C18 column. The mobile phase consisted of methanol:10mM ammonium acetate pH 5.0 (62:38, v/v), delivered at a flow rate of 0.2mL/min. Acceptable accuracy and precision of ±15% were achieved within the linear dynamic range of the calibration curve (2-500ng/mL) for human and mouse plasma samples. Mouse tumor tissue samples required the use of a calibration curve prepared in the same matrix due to the lower recovery of 40% from this matrix. Then, accuracy and precision were within the generally accepted range of ±15% for bioanalytical assays. Ko143 was stable in human plasma for up to 3 repeated freeze-thaw cycles and when stored at room temperature for up to 72h. However, when kept at room temperature in mouse plasma, Ko143 was rapidly degraded by esterase activity, which could be prevented by collection of blood into sodium fluoride-containing tubes and maintaining samples on ice during pretreatment. A preliminary pharmacokinetics study in mice demonstrated the applicability of this assay for ABCG2 resistance studies in vivo.

More about this publication

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences

Volume 913-914
Pages 129-36
Publication date 15-01-2013

Full text links

Publisher website (DOI) 10.1016/j.jchromb.2012.11.003
Europe PubMed Central 23291288
Pubmed 23291288

Where science meets inspired minds

Contact

Plesmanlaan 121
1066CX Amsterdam

020 512 9111 communicatie@nki.nl

Quick links

  • Vacancies
  • News
  • Contact us
  • Media & Press

Follow us on

Disclaimer
Privacy statement
Cookies
Change cookie settings

This site uses cookies

This website uses cookies to ensure you get the best experience on our website.