search

menu

  • Research Research
    • Where science meets inspired minds

    • Back
    • Research
    • Our Science
    • Research Groups
    • Facilities & Platforms
    • Clinical research
    • Find a researcher
    • Publications
    • Knowledge Transfer
  • Careers & study Careers & study
    • Become a leader in cancer research

    • Back
    • Careers & study
    • Vacancies
    • Faculty
    • Scientific staff
    • Scientific support staff
    • Postdoctoral fellows
    • PhD Students
    • Operational staff
    • Clinical fellows
    • Life in Amsterdam
    • Student internships
  • News & Events News & Events
    • Check out our stories and events

    • Back
    • News & Events
    • News
    • Media & Press
    • Calendar
  • About us About us
    • Maximum impact for cancer patients

    • Back
    • About us
    • Our vision
    • Organization
    • Collaborations
    • Responsible Research
    • Support us
    • Visit us
    • Contact us
  • Support us
Support us
  • Home
  • Publications
  • Research
  • Publications
  • Article

Optimal <sup>68</sup>Ga-PSMA and <sup>18</sup>F-PSMA PET window levelling for gross tumour volume delineation in primary prostate cancer.

Cédric Draulans ,
Robin De Roover ,
Uulke A van der Heide ,
Linda Kerkmeijer ,
Robert J Smeenk ,
Floris Pos ,
Wouter V Vogel ,
James Nagarajah ,
Marcel Janssen ,
Sofie Isebaert ,
Frederik Maes ,
Cindy Mai ,
Raymond Oyen ,
Steven Joniau ,
Martina Kunze-Busch ,
Karolien Goffin ,
Karin Haustermans

Abstract

METHODS

Nine 68Ga-PSMA-11 and nine 18F-PSMA-1007 PET scans including GTV delineations of four expert teams (GTVmanual) and a majority-voted GTV (GTVmajority) were assessed with respect to a registered histopathological GTV (GTVhisto) as the gold standard reference. The standard uptake values (SUVs) per voxel were converted to a percentage (SUV%) relative to the SUVmax. The statistically optimised SUV% threshold (SOST) was defined as those that maximises accuracy for threshold-based contouring. A leave-one-out cross-validation receiver operating characteristic (ROC) curve analysis was performed to determine the SOST for each tracer. The SOST analysis was performed twice, first using the GTVhisto contour as training structure (GTVSOST-H) and second using the GTVmajority contour as training structure (GTVSOST-MA) to correct for any limited misregistration. The accuracy of both GTVSOST-H and GTVSOST-MA was calculated relative to GTVhisto in the 'leave-one-out' patient of each fold and compared with the accuracy of GTVmanual.

CONCLUSIONS

Threshold-based contouring using GTVmajority-trained SOSTs achieves an accuracy comparable with manual contours in delineating GTVhisto. The median SOSTs of 41 SUV% for 68Ga-PSMA-11 PET and 44 SUV% for 18F-PSMA-1007 PET form a base for tracer-specific window levelling.

RESULTS

ROC curve analysis for 68Ga-PSMA-11 PET revealed a median threshold of 25 SUV% (range, 22-27 SUV%) and 41 SUV% (40-43 SUV%) for GTVSOST-H and GTVSOST-MA, respectively. For 18F-PSMA-1007 PET, a median threshold of 42 SUV% (39-45 SUV%) for GTVSOST-H and 44 SUV% (42-45 SUV%) for GTVSOST-MA was found. A significant pairwise difference was observed when comparing the accuracy of the GTVSOST-H contours with the median accuracy of the GTVmanual contours (median, - 2.5%; IQR, - 26.5-0.2%; p = 0.020), whereas no significant pairwise difference was found for the GTVSOST-MA contours (median, - 0.3%; IQR, - 4.4-0.6%; p = 0.199).

PURPOSE

This study proposes optimal tracer-specific threshold-based window levels for PSMA PET-based intraprostatic gross tumour volume (GTV) contouring to reduce interobserver delineation variability.

TRIAL REGISTRATION

Clinicaltrials.gov ; NCT03327675; 31-10-2017.

More about this publication

European journal of nuclear medicine and molecular imaging

Volume 48
Issue nr. 4
Pages 1211-1218
Publication date 01-04-2021

Full text links

Publisher website (DOI) 10.1007/s00259-020-05059-4
Europe PubMed Central 33025093
Pubmed 33025093

Where science meets inspired minds

Contact

Plesmanlaan 121
1066CX Amsterdam

020 512 9111 communicatie@nki.nl

Quick links

  • Vacancies
  • News
  • Contact us
  • Media & Press

Follow us on

Disclaimer
Privacy statement
Cookies
Change cookie settings

This site uses cookies

This website uses cookies to ensure you get the best experience on our website.