search

menu

  • Research Research
    • Where science meets inspired minds

    • Back
    • Research
    • Our Science
    • Research Groups
    • Facilities & Platforms
    • Clinical research
    • Find a researcher
    • Publications
    • Knowledge Transfer
  • Careers & study Careers & study
    • Become a leader in cancer research

    • Back
    • Careers & study
    • Vacancies
    • Faculty
    • Scientific staff
    • Scientific support staff
    • Postdoctoral fellows
    • PhD Students
    • Operational staff
    • Clinical fellows
    • Life in Amsterdam
    • Student internships
  • News & Events News & Events
    • Check out our stories and events

    • Back
    • News & Events
    • News
    • Media & Press
    • Calendar
  • About us About us
    • Maximum impact for cancer patients

    • Back
    • About us
    • Our vision
    • Organization
    • Collaborations
    • Responsible Research
    • Support us
    • Visit us
    • Contact us
  • Support us
Support us
  • Home
  • Publications
  • Research
  • Publications
  • Article

Diagnostic Performance of Dedicated Axillary T2- and Diffusion-weighted MR Imaging for Nodal Staging in Breast Cancer.

Robert-Jan Schipper ,
Marie-Louise Paiman ,
Regina G H Beets-Tan ,
Patricia J Nelemans ,
Bart de Vries ,
Esther M Heuts ,
Koen K van de Vijver ,
Kristien B Keymeulen ,
Boudewijn Brans ,
Marjolein L Smidt ,
Marc B I Lobbes

Abstract

MATERIALS AND METHODS

Institutional review board approval and informed consent were obtained. Fifty women (mean age, 60 years; range, 22-80 years) underwent high-spatial-resolution axillary 3.0-T T2-weighted imaging without fat suppression and DW imaging (b = 0, 500, and 800 sec/mm(2)), followed by either sentinel lymph node biopsy (SLNB) or axillary lymph node dissection. Two radiologists independently scored each lymph node on a confidence level scale from 0 (benign) to 4 (malignant), first on T2-weighted MR images, then on DW MR images. Two researchers independently measured the mean apparent diffusion coefficient (ADC) of each lymph node. Diagnostic performance parameters were calculated on the basis of node-by-node and patient-by-patient validation.

CONCLUSION

Dedicated high-spatial-resolution axillary T2-weighted MR imaging showed good specificity on the basis of node-by-node and patient-by-patient validation, with good interobserver agreement. However, its NPV is still insufficient to substitute it for SLNB for exclusion of axillary lymph node metastasis. DW MR imaging and ADC measurement were of no added value.

RESULTS

With respective node-by-node and patient-by-patient validation, T2-weighted MR imaging had a specificity of 93%-97% and 87%-95%, sensitivity of 32%-55% and 50%-67%, negative predictive value (NPV) of 88%-91% and 86%-89%, positive predictive value (PPV) of 60%-70% and 62%-75%, and area under the receiver operating characteristic curve (AUC) of 0.78 and 0.80-0.88, with good interobserver agreement (κ = 0.70). The addition of DW MR imaging resulted in lower specificity (59%-88% and 50%-84%), higher sensitivity (45%-64% and 75%-83%), comparable NPV (89% and 90%-91%), lower PPV (23%-42% and 34%-60%), and lower AUC (0.68-0.73 and 0.70-0.86). ADC measurement resulted in a specificity of 63%-64% and 61%-63%, sensitivity of 41% and 67%, NPV of 85% and 85%-86%, PPV of 18% and 35%-36%, and AUC of 0.54-0.58 and 0.69-0.74, respectively, with excellent interobserver agreement (intraclass correlation coefficient, 0.83).

PURPOSE

To evaluate the diagnostic performance of unenhanced axillary T2-weighted and diffusion-weighted (DW) magnetic resonance (MR) imaging for axillary nodal staging in patients with newly diagnosed breast cancer, with node-by-node and patient-by-patient validation.

More about this publication

Radiology

Volume 275
Issue nr. 2
Pages 345-55
Publication date 01-05-2015

Full text links

Publisher website (DOI) 10.1148/radiol.14141167
Europe PubMed Central 25513854
Pubmed 25513854

Where science meets inspired minds

Contact

Plesmanlaan 121
1066CX Amsterdam

020 512 9111 communicatie@nki.nl

Quick links

  • Vacancies
  • News
  • Contact us
  • Media & Press

Follow us on

Disclaimer
Privacy statement
Cookies
Change cookie settings

This site uses cookies

This website uses cookies to ensure you get the best experience on our website.