search

menu

  • Research Research
    • Where science meets inspired minds

    • Back
    • Research
    • Our Science
    • Research Groups
    • Facilities & Platforms
    • Clinical research
    • Find a researcher
    • Publications
    • Knowledge Transfer
  • Careers & study Careers & study
    • Become a leader in cancer research

    • Back
    • Careers & study
    • Vacancies
    • Faculty
    • Scientific staff
    • Scientific support staff
    • Postdoctoral fellows
    • PhD Students
    • Operational staff
    • Clinical fellows
    • Life in Amsterdam
    • Student internships
  • News & Events News & Events
    • Check out our stories and events

    • Back
    • News & Events
    • News
    • Media & Press
    • Calendar
  • About us About us
    • Maximum impact for cancer patients

    • Back
    • About us
    • Our vision
    • Organization
    • Collaborations
    • Responsible Research
    • Support us
    • Visit us
    • Contact us
  • Support us
Support us
  • Home
  • Publications
  • Research
  • Publications
  • Article

Tumor Trailing for Liver SBRT on the MR-Linac.

Martin Fast ,
Agustinus van de Schoot ,
Tessa van de Lindt ,
Casper Carbaat ,
Uulke van der Heide ,
Jan-Jakob Sonke

Abstract

METHODS AND MATERIALS

For 17 patients with oligometastatic liver disease, midposition SBRT treatment plans (3 × 20 Gy, 11-beam intensity modulated radiotherapy) were created for the Elekta Unity MR-Linac. Treatment was simulated using an in-house-developed delivery emulator. Respiratory motion was modelled as the superposition of periodic motion (patient-specific amplitude, 4-second period) and the following baseline motion scenarios: a continuous linear drift (0.5 mm/min), (2) a single shift halfway through treatment (10 mm), (3) a periodic drift (amplitude: 5 mm, period: 5 minutes), or (4) MR imaging-measured baseline drifts. Delivered dose was calculated under full consideration of the patient and machine motion interplay. In addition, trailing was experimentally validated on the MR-Linac using a programmable motion phantom.

CONCLUSION

Tumor trailing on the MR-Linac restores target dose in liver SBRT in the case of baseline motion for the presented patient cohort.

RESULTS

The average simulated delivery and beam-on times were 15.9 and 8.7 minutes, respectively. An imaging frequency of ≥1 Hz was deemed necessary for trailing. Trailing increased the median gross tumor volume D98% dose by 1.9 Gy (linear drift), 1.2 Gy (single shift), 0.7 Gy (periodic drift), and 0.5 to 1.5 Gy (measured drifts) per fraction, compared with a conventional delivery. In the phantom experiments, the 3%/2 mm local gamma pass rate nearly doubled to 98% when using trailing.

PURPOSE

Tumor trailing is a treatment delivery technique that continuously adjusts the beam aperture according to the last available time-averaged position of the target. This study investigates whether tumor trailing on a magnetic resonance (MR) linear accelerator (linac) can improve target coverage in liver stereotactic body radiation therapy (SBRT) in the case of baseline motion.

More about this publication

International journal of radiation oncology, biology, physics

Volume 103
Issue nr. 2
Pages 468-478
Publication date 01-02-2019

Full text links

Publisher website (DOI) 10.1016/j.ijrobp.2018.09.011
Europe PubMed Central 30243573
Pubmed 30243573

Where science meets inspired minds

Contact

Plesmanlaan 121
1066CX Amsterdam

020 512 9111 communicatie@nki.nl

Quick links

  • Vacancies
  • News
  • Contact us
  • Media & Press

Follow us on

Disclaimer
Privacy statement
Cookies
Change cookie settings

This site uses cookies

This website uses cookies to ensure you get the best experience on our website.