search

menu

  • Research Research
    • Where science meets inspired minds

    • Back
    • Research
    • Our Science
    • Research Groups
    • Facilities & Platforms
    • Clinical research
    • Find a researcher
    • Publications
    • Knowledge Transfer
  • Careers & study Careers & study
    • Become a leader in cancer research

    • Back
    • Careers & study
    • Vacancies
    • Faculty
    • Scientific staff
    • Scientific support staff
    • Postdoctoral fellows
    • PhD Students
    • Operational staff
    • Clinical fellows
    • Life in Amsterdam
    • Student internships
  • News & Events News & Events
    • Check out our stories and events

    • Back
    • News & Events
    • News
    • Media & Press
    • Calendar
  • About us About us
    • Maximum impact for cancer patients

    • Back
    • About us
    • Our vision
    • Organization
    • Collaborations
    • Responsible Research
    • Support us
    • Visit us
    • Contact us
  • Support us
Support us
  • Home
  • Publications
  • Research
  • Publications
  • Article

Use of leftovers of monoclonal antibody products after partial extraction - A microbiological safety study.

A Hedvig Arnamo ,
Alwin Dr Huitema ,
Jos H Beijnen ,
Bastiaan Nuijen

Abstract

METHODS

From the daily practice of the Central Preparation Unit of the Netherlands Cancer Institute, used monoclonal antibody product vials were collected. To examine the integrity of the primary packaging, a VDT/S Vacuum Leak tester from Erweka was used. Vials were punctured with different types of spikes or a needle prior to experiments and examined for leakage afterward. In addition, microbiological monitoring was performed by broth simulation of the preparation method.

CONCLUSION

When working under aseptic preparation conditions and making use of appropriate needle, the risk of contamination is acceptably low to justify storage and reuse of leftover monoclonal antibody product from a microbiological perspective. The spikes tested lead to an unacceptably high level of loss of integrity and subsequent risk of microbiological contamination if stored in a non-classified environment. We concluded that these results could be applied generically to all monoclonal antibody products with a primary packaging composed of a glass vial and rubber stopper.

RESULTS

All vials (631 vials, 18 different monoclonal antibody products) showed no leakage after puncturing with a 18 G needle. However, the use of a spike system resulted in leakage in 108 of the 435 tested vials. Results from the broth simulations confirmed a higher risk of contamination after puncturing with a spike as compared to needle-punctured vials (0.5% vs. 0.05%).

BACKGROUND/PURPOSE

In the absence of thorough microbiological, chemical and physical stability data, high amounts of pharmaceutical products, from which the seal has been broken, are to be discarded after preparation. We performed a generic microbiological validation study for several marketed monoclonal antibody products, in order to define conditions under which leftovers from partially extracted product can be used in order to minimize loss.

More about this publication

Journal of oncology pharmacy practice : official publication of the International Society of Oncology Pharmacy Practitioners

Volume 26
Issue nr. 2
Pages 368-378
Publication date 01-03-2020

Full text links

Publisher website (DOI) 10.1177/1078155219850297
Europe PubMed Central 31156055
Pubmed 31156055

Where science meets inspired minds

Contact

Plesmanlaan 121
1066CX Amsterdam

020 512 9111 communicatie@nki.nl

Quick links

  • Vacancies
  • News
  • Contact us
  • Media & Press

Follow us on

Disclaimer
Privacy statement
Cookies
Change cookie settings

This site uses cookies

This website uses cookies to ensure you get the best experience on our website.