search

menu

  • Research Research
    • Where science meets inspired minds

    • Back
    • Research
    • Our Science
    • Research Groups
    • Facilities & Platforms
    • Clinical research
    • Find a researcher
    • Publications
    • Knowledge Transfer
  • Careers & study Careers & study
    • Become a leader in cancer research

    • Back
    • Careers & study
    • Vacancies
    • Faculty
    • Scientific staff
    • Scientific support staff
    • Postdoctoral fellows
    • PhD Students
    • Operational staff
    • Clinical fellows
    • Life in Amsterdam
    • Student internships
  • News & Events News & Events
    • Check out our stories and events

    • Back
    • News & Events
    • News
    • Media & Press
    • Calendar
  • About us About us
    • Maximum impact for cancer patients

    • Back
    • About us
    • Our vision
    • Organization
    • Collaborations
    • Responsible Research
    • Support us
    • Visit us
    • Contact us
  • Support us
Support us
  • Home
  • Publications
  • Research
  • Publications
  • Article

Ultrasound-based navigation for open liver surgery using active liver tracking.

Jasper N Smit ,
Koert F D Kuhlmann ,
Oleksandra V Ivashchenko ,
Bart R Thomson ,
Thomas Langø ,
Niels F M Kok ,
Matteo Fusaglia ,
Theo J M Ruers

Abstract

METHODS

Electromagnetic (EM) tracking was used for organ tracking and movement of the transducer. After laparotomy, a sensor was attached to the liver surface while the EM-tracked US transducer enabled image acquisition and landmark digitization. Landmarks surrounding the lesion were selected during patient-specific preoperative 3D planning and identified for registration during surgery. Endpoints were accuracy and additional times of the investigative steps. Accuracy was computed at the center of the target lesion.

CONCLUSION

We developed a navigation method combining ultrasound with active liver tracking for organ motion compensation, with an accuracy below 10 mm. Fixation of the liver sensor near the target lesion compensates for local movement and contributes to improved reliability during navigation. This represents an important step forward in providing surgical navigation throughout the procedure.

RESULTS

In total, 22 navigated procedures were performed. Navigation provided useful visualization of preoperative 3D models and their overlay on US imaging. Landmark-based registration resulted in a mean fiducial registration error of 10.3 ± 4.3 mm, and a mean target registration error of 8.5 ± 4.2 mm. Navigation was available after an average of 12.7 min.

TRIAL REGISTRATION

This study is registered in the Netherlands Trial Register (number NL7951).

PURPOSE

Despite extensive preoperative imaging, intraoperative localization of liver lesions after systemic treatment can be challenging. Therefore, an image-guided navigation setup is explored that links preoperative diagnostic scans and 3D models to intraoperative ultrasound (US), enabling overlay of detailed diagnostic images on intraoperative US. Aim of this study is to assess the workflow and accuracy of such a navigation system which compensates for liver motion.

More about this publication

International journal of computer assisted radiology and surgery

Volume 17
Issue nr. 10
Pages 1765-1773
Publication date 01-10-2022

Full text links

Publisher website (DOI) 10.1007/s11548-022-02659-3
Europe PubMed Central 35622201
Pubmed 35622201

Where science meets inspired minds

Contact

Plesmanlaan 121
1066CX Amsterdam

020 512 9111 communicatie@nki.nl

Quick links

  • Vacancies
  • News
  • Contact us
  • Media & Press

Follow us on

Disclaimer
Privacy statement
Cookies
Change cookie settings

This site uses cookies

This website uses cookies to ensure you get the best experience on our website.