search

menu

  • Research Research
    • Where science meets inspired minds

    • Back
    • Research
    • Our Science
    • Research Groups
    • Facilities & Platforms
    • Clinical research
    • Find a researcher
    • Publications
    • Knowledge Transfer
  • Careers & study Careers & study
    • Become a leader in cancer research

    • Back
    • Careers & study
    • Vacancies
    • Faculty
    • Scientific staff
    • Scientific support staff
    • Postdoctoral fellows
    • PhD Students
    • Operational staff
    • Clinical fellows
    • Life in Amsterdam
    • Student internships
  • News & Events News & Events
    • Check out our stories and events

    • Back
    • News & Events
    • News
    • Media & Press
    • Calendar
  • About us About us
    • Maximum impact for cancer patients

    • Back
    • About us
    • Our vision
    • Organization
    • Collaborations
    • Responsible Research
    • Support us
    • Visit us
    • Contact us
  • Support us
Support us
  • Home
  • Publications
  • Research
  • Publications
  • Article

Quantitative aspects of the analysis of the monoclonal antibody trastuzumab using high-performance liquid chromatography coupled with electrospray mass spectrometry.

Carola W N Damen ,
Hilde Rosing ,
Jan H M Schellens ,
Jos H Beijnen

Abstract

The analytical possibilities of quantification of the intact monoclonal antibody trastuzumab by high-performance liquid chromatography coupled with electrospray mass spectrometry (HPLC-ESI-MS) were investigated. To clarify the results obtained by LC-MS, complementary experiments were performed using direct UV-spectrophotometry and high-performance liquid chromatography coupled with ultraviolet detection (HPLC-UV). A polystyrene-divinylbenzene (POROS) column was applied with gradient elution using formic acid 0.08% (v/v) in water and formic acid 0.08% (v/v) in acetonitrile as mobile phase for chromatographic analysis. Quantification on LC-MS was performed by using the peak area of the total ion current (TIC) chromatograms of one charge state. Non-linearity and sensitivity loss were the major limitations observed with the LC-MS method, of which the non-linearity is most likely caused by detector saturation. The sensitivity loss during analysis could be reduced by lowering the MS source temperature. This parameter is critical in creating a robust LC-MS system for the quantitative analysis of trastuzumab.

More about this publication

Journal of pharmaceutical and biomedical analysis

Volume 46
Issue nr. 3
Pages 449-55
Publication date 13-02-2008

Full text links

Publisher website (DOI) 10.1016/j.jpba.2007.11.002
Europe PubMed Central 18096347
Pubmed 18096347

Where science meets inspired minds

Contact

Plesmanlaan 121
1066CX Amsterdam

020 512 9111 communicatie@nki.nl

Quick links

  • Vacancies
  • News
  • Contact us
  • Media & Press

Follow us on

Disclaimer
Privacy statement
Cookies
Change cookie settings

This site uses cookies

This website uses cookies to ensure you get the best experience on our website.