search

menu

  • Research Research
    • Where science meets inspired minds

    • Back
    • Research
    • Our Science
    • Research Groups
    • Facilities & Platforms
    • Clinical research
    • Find a researcher
    • Publications
    • Knowledge Transfer
  • Careers & study Careers & study
    • Become a leader in cancer research

    • Back
    • Careers & study
    • Vacancies
    • Faculty
    • Scientific staff
    • Scientific support staff
    • Postdoctoral fellows
    • PhD Students
    • Operational staff
    • Clinical fellows
    • Life in Amsterdam
    • Student internships
  • News & Events News & Events
    • Check out our stories and events

    • Back
    • News & Events
    • News
    • Media & Press
    • Calendar
  • About us About us
    • Maximum impact for cancer patients

    • Back
    • About us
    • Our vision
    • Organization
    • Collaborations
    • Responsible Research
    • Support us
    • Visit us
    • Contact us
  • Support us
Support us
  • Home
  • Publications
  • Research
  • Publications
  • Article

Renal clearance of fluorescent agents can compromise image-guided surgery along the urinary tract.

Anne-Claire Berrens ,
Tessa Buckle ,
Matthias N van Oosterom ,
Leon J Slof ,
Belle M Melsert ,
Jakko A Nieuwenhuijzen ,
Esther M K Wit ,
Pim J van Leeuwen ,
Henk G van der Poel ,
Fijs W B van Leeuwen

Abstract

SUBJECTS AND METHODS

Sixteen patients who underwent robot-assisted radical prostatectomy (RARP) with lymph node dissection received an intradermal injection of fluorescein. The slow-release of the fluorescein from the skin into the lymph- and bloodstream were used as a pharmacokinetic model for slow release from receptor-targeted agents. The presence of fluorescein in the urine and the surgical dissection planes around the prostate (representative of cancer margins) during RARP were evaluated. Suction, gauze and irrigation were used to try and reduce fluorescent background signals according to standard operating protocol.

CONCLUSIONS

Renally excreted fluorescent agents risk contamination of the surgical field and possible dissection margins along the urinary tract, a feature that, without proper counter measures, could compromise the accuracy of intra-operative imaging by creating false-positive findings. A clear example of this was the observed bladder neck staining with fluorescein.

RESULTS

Fluorescein was detected in the urine in the bedside catheter bag after a median of 1.3 h after agent administration and in the surgical field after opening the bladder neck as part of RARP (median of 2.4 h after injection). Suction and application of gauze helped to reduce contamination, but suction combined with irrigation with lukewarm NaCl 0.9% was shown to be most effective. Fluorescein accumulation was seen in the tissue surrounding the bladder neck in 80% of patients.

OBJECTIVES

To study the effect of renally cleared fluorescent agents on image-guided surgery along the urinary tract by using the renally cleared, non-tumour-specific, fluorescent dye fluorescein.

More about this publication

BJU international

Volume 136
Issue nr. 3
Pages 515-522
Publication date 01-09-2025

Full text links

Publisher website (DOI) 10.1111/bju.16804
Europe PubMed Central 40588445
Pubmed 40588445

Where science meets inspired minds

Contact

Plesmanlaan 121
1066CX Amsterdam

020 512 9111 communicatie@nki.nl

Quick links

  • Vacancies
  • News
  • Contact us
  • Media & Press

Follow us on

Disclaimer
Privacy statement
Cookies
Change cookie settings

This site uses cookies

This website uses cookies to ensure you get the best experience on our website.