search

menu

  • Research Research
    • Where science meets inspired minds

    • Back
    • Research
    • Our Science
    • Research Groups
    • Facilities & Platforms
    • Clinical research
    • Find a researcher
    • Publications
    • Knowledge Transfer
  • Careers & study Careers & study
    • Become a leader in cancer research

    • Back
    • Careers & study
    • Vacancies
    • Faculty
    • Scientific staff
    • Scientific support staff
    • Postdoctoral fellows
    • PhD Students
    • Operational staff
    • Clinical fellows
    • Life in Amsterdam
    • Student internships
  • News & Events News & Events
    • Check out our stories and events

    • Back
    • News & Events
    • News
    • Media & Press
    • Calendar
  • About us About us
    • Maximum impact for cancer patients

    • Back
    • About us
    • Our vision
    • Organization
    • Collaborations
    • Responsible Research
    • Support us
    • Visit us
    • Contact us
  • Support us
Support us
  • Home
  • Publications
  • Research
  • Publications
  • Article

Deterioration of Intended Target Volume Radiation Dose Due to Anatomical Changes in Patients with Head-and-Neck Cancer.

Olga Hamming-Vrieze ,
Simon van Kranen ,
Iris Walraven ,
Arash Navran ,
Abrahim Al-Mamgani ,
Margot Tesselaar ,
Michiel van den Brekel ,
Jan-Jakob Sonke

Abstract

Delivered radiation dose can differ from intended dose. This study quantifies dose deterioration in targets, identifies predictive factors, and compares dosimetric to clinical patient selection for adaptive radiotherapy in head-and-neck cancer patients. One hundred and eighty-eight consecutive head-and-neck cancer patients treated up to 70 Gy were analyzed. Daily delivered dose was calculated, accumulated, and compared to the planned dose. Cutoff values (1 Gy/2 Gy) were used to assess plan deterioration in the highest/lowest dose percentile (D1/D99). Differences in clinical factors between patients with/without dosimetric deterioration were statistically tested. Dosimetric deterioration was evaluated in clinically selected patients for adaptive radiotherapy with CBCT. Respectively, 16% and 4% of patients had deterioration over 1 Gy in D99 and D1 in any of the targets, this was 5% (D99) and 2% (D1) over 2 Gy. Factors associated with deterioration of D99 were higher baseline weight/BMI, weight gain early in treatment, and smaller PTV margins. The sensitivity of visual patient selection with CBCT was 22% for detection of dosimetric changes over 1 Gy. Large dose deteriorations in targets occur in a minority of patients. Clinical prediction based on patient characteristics or CBCT is challenging and dosimetric selection tools seem warranted to identify patients in need for ART, especially in treatment with small PTV margins.

More about this publication

Cancers

Volume 13
Issue nr. 17
Publication date 24-08-2021

Full text links

Publisher website (DOI) 10.3390/cancers13174253
Europe PubMed Central 34503061
Pubmed 34503061

Where science meets inspired minds

Contact

Plesmanlaan 121
1066CX Amsterdam

020 512 9111 communicatie@nki.nl

Quick links

  • Vacancies
  • News
  • Contact us
  • Media & Press

Follow us on

Disclaimer
Privacy statement
Cookies
Change cookie settings

This site uses cookies

This website uses cookies to ensure you get the best experience on our website.