search

menu

  • Research Research
    • Where science meets inspired minds

    • Back
    • Research
    • Our Science
    • Research Groups
    • Facilities & Platforms
    • Clinical research
    • Find a researcher
    • Publications
    • Knowledge Transfer
  • Careers & study Careers & study
    • Become a leader in cancer research

    • Back
    • Careers & study
    • Vacancies
    • Faculty
    • Scientific staff
    • Scientific support staff
    • Postdoctoral fellows
    • PhD Students
    • Operational staff
    • Clinical fellows
    • Life in Amsterdam
    • Student internships
  • News & Events News & Events
    • Check out our stories and events

    • Back
    • News & Events
    • News
    • Media & Press
    • Calendar
  • About us About us
    • Maximum impact for cancer patients

    • Back
    • About us
    • Our vision
    • Organization
    • Collaborations
    • Responsible Research
    • Support us
    • Visit us
    • Contact us
  • Support us
Support us
  • Home
  • Publications
  • Research
  • Publications
  • Article

3D Dosimetric verification of volumetric-modulated arc therapy by portal dosimetry.

Anton Mans ,
Peter Remeijer ,
Igor Olaciregui-Ruiz ,
Markus Wendling ,
Jan-Jakob Sonke ,
Ben Mijnheer ,
Marcel van Herk ,
Joep C Stroom

Abstract

MATERIALS AND METHODS

Several modifications to our existing approach were implemented to make the method applicable to VMAT: (i) gantry angle-resolved data acquisition, (ii) calculation of the patient transmission, (iii) compensation for detector 'flex' and (iv) 3D dose reconstruction and evaluation.

CONCLUSIONS

Our portal dosimetry method was successfully adapted for verification of VMAT treatments, pre-treatment as well as in vivo.

RESULTS

Planned and EPID-(Electronic Portal Image Detector)-reconstructed dose distributions show good agreement for pre-treatment verification of two prostate, a stereotactic lung and a head-and-neck VMAT plan and for in vivo verification of VMAT treatments of prostate and lung cancer. Averaged over pre-treatment verifications, planned and measured isocentre dose ratios were -1.2% (range [-4.7%,1.8%]). 3D gamma analysis (3% maximum dose, 3mm) revealed mean gamma gamma(mean)=0.37 [0.34,0.39], maximum 1% gamma gamma(1%)=0.72 [0.66,0.81] and percentage of points with gamma1 P(gamma)(1)=99% [97%,100%]. For in vivo verification, the average isocentre dose ratio was -1.2% [-0.8%,-1.7%], gamma(mean)=0.52 [0.40,0.64], gamma(1%)=0.92 [0.76,1.08] and P(gamma)(1)=96% [93%,100%].

BACKGROUND AND PURPOSE

To demonstrate the feasibility of back-projection portal dosimetry for accurate 3D dosimetric verification of volumetric-modulated arc therapy (VMAT), pre-treatment as well as in vivo.

More about this publication

Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology

Volume 94
Issue nr. 2
Pages 181-7
Publication date 01-02-2010

Full text links

Publisher website (DOI) 10.1016/j.radonc.2009.12.020
Europe PubMed Central 20089323
Pubmed 20089323

Where science meets inspired minds

Contact

Plesmanlaan 121