search

menu

  • Research Research
    • Where science meets inspired minds

    • Back
    • Research
    • Our Science
    • Research Groups
    • Facilities & Platforms
    • Clinical research
    • Find a researcher
    • Publications
    • Knowledge Transfer
  • Careers & study Careers & study
    • Become a leader in cancer research

    • Back
    • Careers & study
    • Vacancies
    • Faculty
    • Scientific staff
    • Scientific support staff
    • Postdoctoral fellows
    • PhD Students
    • Operational staff
    • Clinical fellows
    • Life in Amsterdam
    • Student internships
  • News & Events News & Events
    • Check out our stories and events

    • Back
    • News & Events
    • News
    • Media & Press
    • Calendar
  • About us About us
    • Maximum impact for cancer patients

    • Back
    • About us
    • Our vision
    • Organization
    • Collaborations
    • Responsible Research
    • Support us
    • Visit us
    • Contact us
  • Support us
Support us
  • Home
  • Publications
  • Research
  • Publications
  • Article

Differences between planned and delivered dose for head and neck cancer, and their consequences for normal tissue complication probability and treatment adaptation.

Jolien Heukelom ,
Michael E Kantor ,
Abdallah S R Mohamed ,
Hesham Elhalawani ,
Esengul Kocak-Uzel ,
Timothy Lin ,
Jinzhong Yang ,
Michalis Aristophanous ,
Coen R Rasch ,
Clifton David Fuller ,
Jan-Jakob Sonke

Abstract

MATERIALS AND METHODS

For 52 patients, daily doses were accumulated to estimate the delivered dose. The difference from planned dose was analyzed for CTVs and 9 organs-at-risk (OAR). ΔNTCP was calculated for xerostomia, dysphagia, parotid gland dysfunction and tube feeding dependency at 6 months. ART was deemed necessary if ΔNTCP was >5%. The positive predicted value (PPV) was calculated for identification of ART-patients by clinical judgement, and ΔNTCP at fraction 10 and 15.

CONCLUSION

To identify patients accurately for ART, NTCP calculations based on the dose differences between planned and delivered dose at fraction 10 are superior to clinical judgement.

RESULTS

ΔNTCP >5% was seen five times for dysphagia and twice for the other toxicities. Only 5/9 patients with any ΔNTCP >5% clinically received ART, although ART had been done for 13/52 patients (PPV: 0.38). PPV was 0.86 and 0.75 for accumulated dose at fraction 10 and 15, respectively, using a ΔNTCP cut-off for the allocation of ART of 5%. Using other ΔNTCP cut-offs did not substantially improve PPV. With this cut-off the negative predictive value was 0.93 for ΔNTCP method of fraction 10 and fraction 15, and 0.90 for clinical judgement.

BACKGROUND AND PURPOSE

Anatomical changes induce differences between planned and delivered dose. Adaptive radiotherapy (ART) may reduce these differences but the optimal implementation is insufficiently clear. The aims of this study were to quantify the difference between planned and delivered dose in HNC patients, assess the consequential difference in normal tissue complication probability (ΔNTCP) and to explore the value of ΔNTCP as an objective selection strategy for ART.

More about this publication

Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology

Volume 142
Pages 100-106
Publication date 01-01-2020

Full text links

Publisher website (DOI) 10.1016/j.radonc.2019.07.034
Europe PubMed Central 31431381
Pubmed 31431381

Where science meets inspired minds

Contact

Plesmanlaan 121